3-36
(7) SUCTION FAN LEVEL
Select the force (air volume of fan) to suck the
media to the platen.
# S U C T I O N F A N L E V E L
> X X : H I G H
XX: Selected media number
<Parameter (choice input)>
HIGH
Media is sucked with the largest air volume.
NORMAL
Media is sucked with medium air volume.
LOW
Media is sucked with small air volume.
OFF
Stops the suction fan.
Note
Select [LOW] for less elastic cloth media that easily generates wrinkles.
–
(8) AFTERHEATER INIT
Set the afterheater temperature. However, when
“**” is set, the afterheater does not work.
(When temperature unit is Centigrade)
# A F T E R H E A T E R T
> 0 1 : 3 0 ° C
(When temperature unit is Fahrenheit)
# A F T E R H E A T E R T
> 0 1 : 0 8 6 ° F
<Parameter (numeric input)>
15°C to 70°C
Centigrade temperature setting range
59°F to 158°F
Fahrenheit temperature setting range
(9) PRINTHEATER INIT
Set the print heater temperature. However, when
“**” is set, the print heater does not work.
(When temperature unit is Centigrade)
# P R I N T H E A T E R T
> 0 1 : 4 0 º C
(When temperature unit is Fahrenheit)
# P R I N T H E A T E R T
> 0 1 : 1 0 4 º F
<Parameter (numeric input)>
15°C to 55°C
Centigrade temperature setting range
59°F to 131°F
Fahrenheit temperature setting range