35
[ESC+F] Sequential Number
ESC
F
Parameter
Hexadecimal code
<1B>
16
<46>
16
aaaabcccc(,dd,ee,f)
Initial value
None
When the power is OFF
The set parameter is not maintained.
Valid range within items
The set parameter becomes invalid.
Valid range and term of
command
Valid range between items
The set parameter becomes invalid.
[Function]
Specifying prior to the data specification command of font or barcode, and printing specified data in
a sequential order.
[Format]
<F>aaaabcccc(,dd,ee,f)
-
Parameter
a [Print quantity specification of identical contents] = Valid range : 1 to 9999
b [Increasing and decreasing specification]
+ : Addition
- : Subtraction
c [Setting of increasing and decreasing value] = Valid range : 1 to 9999
d [Valid digit number for sequential number] = Valid range : 1 to 99 When omitted: 8 (omissible)
e [Low-order invalid digit number] = Valid range : 0 to 99 When omitted: 0 (omissible)
Starting with the rightmost position
f [Specification of Decimal/Hex sequential number]
0 : Decimal number When omitted: 0 (omissible)
1 : Hexadecimal
[Coding Example]
Print quantity specification of identical contents: 1, Increasing and decreasing specification: +,
Setting of increasing and decreasing value: 1, Valid digit number for sequential number: 5, Loworder
invalid digit number: 0
<A>
<V>100<H>100<P>2<L>0202
<F>1+1,5,0
<XU>10000
<Q>2
<Z>
[Supplementary Explanation]
-
Sequential number can be specified up to 8 points per format.
-
Next print data from <F> command will be the initial value of sequential number.
-
Specify the required number of digits for sequential number to print it properly. If not specified,
sequential numbers may not be printed properly.
-
Specification of Black/White Reverse Print <(> is not valid for sequential numbered data.
-
Auto Linefeed <E> is not available.
-
Need to print font or barcode to print sequential number.
Summary of Contents for SG112 ex
Page 1: ...For printer model Programming Reference...
Page 10: ...9 Basic Specifications 513 Connector pin assignment 514...
Page 221: ...220 MaxiCode can specify from 01H to FFH...
Page 236: ...235 QR Code Kanji mode Code table...
Page 237: ...236...
Page 238: ...237...
Page 239: ...238...
Page 240: ...239...
Page 241: ...240...
Page 242: ...241...
Page 243: ...242...
Page 244: ...243...
Page 245: ...244...
Page 246: ...245...
Page 247: ...246...
Page 248: ...247...
Page 249: ...248...
Page 250: ...249...
Page 251: ...250...
Page 252: ...251...
Page 253: ...252...
Page 254: ...253...
Page 255: ...254...
Page 268: ...267 QR Code Kanji mode Code table...
Page 269: ...268...
Page 270: ...269...
Page 271: ...270...
Page 272: ...271...
Page 273: ...272...
Page 274: ...273...
Page 275: ...274...
Page 276: ...275...
Page 277: ...276...
Page 278: ...277...
Page 279: ...278...
Page 280: ...279...
Page 281: ...280...
Page 282: ...281...
Page 283: ...282...
Page 284: ...283...
Page 285: ...284...
Page 286: ...285...
Page 287: ...286...
Page 480: ...479 Near Full Release Near Full 0 MB 2 95 MB Remaining 0 95 MB Remaining 1 95 MB...
Page 491: ...490 Connector Pin Assignment Pin No Name 1 VBus 2 Data D 3 Data D 4 GND...
Page 515: ...514 Connector pin assignment Pin no Name 1 VBus 2 Data D 3 Data D 4 GND...