ALM CODE
ALARM
DEFINITION
MJB06
IPC MSGQ Over
IPC TX queue full error has occurred in the MCP.
Alarm data = IPC Queue type
(MCP-LAN, MCP-SCP, MCP-LCP1, MCP-LCP2)
MJB06
IPC MSGQ Under
IPC TX queue under error has occurred in the MCP.
Alarm data = IPC Queue type
(MCP-LAN, MCP-SCP, MCP-LCP1, MCP-LCP2)
MJB07 Task
MSGQ
Over
Task MSG queue full error has occurred in the MCP.
Alarm data = Error Task Kind
(CNFG, ERRH, NPER, MSGH, DIGH, SMART, CALL, PPER,
SMDR, TMMC, IDLE)
MJB07
Task MSGQ Un-
der
Task MSG queue under error has occurred in the MCP.
Alarm data = Error Task Kind
(CNFG, ERRH, NPER, MSGH, DIGH, SMART, CALL, PPER,
SMDR, TMMC, IDLE)
MJC01 DTMF
Fault
An abnormal interrupt has occurred in the system DTMF
resources.
Alarm data = DTMF Receiver number (BASE, MISC)
MJC02 Tone
Fault
An abnormal interrupt has occurred in the system tone resources,
i.e. busy, ringback, error, no more calls etc.
Alarm data = TONE Receiver number (BASE, MISC)
MJC10 AA-DTMF
Fault
An abnormal fault reported in one of the systems AA card DTMF
resources.
Alarm data = Cabinet, Slot, Port (Cx–Syy-Pzz)
MJC11 AA-MFR
Rec
An abnormal fault reported in one of the systems AA card DTMF
resources has recovered.
Alarm data = Cabinet, Slot, Port (Cx–Syy-Pzz)
MJC12 E911
Restart
The E911 card has restarted.
Alarm data = Cabinet, Slot (Cx–Syy)
MJC13 E911
Block
The E911 card has restarted because the system detected the
card does not work correctly.
Alarm data = Cabinet, Slot (Cx–Syy)
MJC14 VoIP
Restart
The ITM3/MGI card has restarted.
Alarm data = Cabinet, Slot (Cx–Syy)
MJC15 VoIP
Block
The ITM3/MGI card has restarted because the system detected
the card does not work correctly.
Alarm data = Cabinet, Slot (Cx–Syy)
MJD01
Sync Failure
Clocking on TEPRI cards has become asynchronous.
MJD02
Sync Recovery
Clocking on TEPRI cards has become synchronous.
MJD03 Red
Alarm
Locally detected loss of PCM carrier on TEPRI card for more
than 250 ms.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD04
Red Alarm Rec
PCM carrier detected locally on TEPRI cards.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD05 Yellow
Alarm
Remotely detected failure transmitted in frame on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD06
Yellow Alarm Rec
Remotely detected failure restored transmitted on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD07 Blue
Alarm
All 1’s being transmitted on facility on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD08
Blue Alarm Rec
A blue alarm condition has been cleared.