SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 204 (Page 1 of 1)
MMC: 204
COMMON BELL CONTROL
FOR:
ALL
SYSTEMS
Purpose:
Determines whether the common bell relay contacts have an interrupted or
continuous closure when activated. If interrupted is chosen, the relay follows an internal
ring pattern of one second closed followed by three seconds open.
By default, all common bell relay pairs are assigned as:
DCS
Compact II
816
408 / 408i
i
DCS500
i
DCS100
OS500
380x
363–365
362
361
380x
363–365 3991
ACTION DISPLAY
1. Open programming and select
204
Display shows current setting
[3801]COM. BELL
CONTINUOUS
OR
[363] COM/LD BELL
CONTINUOUS
2. Dial common bell number
OR
Press VOLUME keys to make selection of
common bell numbers and press RIGHT soft key
to advance cursor
3. Dial 0 for continuous or 1 for interrupted operation
OR
Press VOLUME keys to scroll through options
Press RIGHT soft key to return to step 2
[3801]COM. BELL
INTERRUPTED
OR
[363] COM/LD BELL
INTERRUPTED
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Continuous
Related Items:
MMC 203 Assign UA Device
MMC 219 Common Relay Service Type
MMC 601 Assign Station Group