SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 503 (Page 1 of 1)
MMC: 503
TRUNK-WIDE TIMERS
FOR:
ALL
SYSTEMS
Purpose:
Allows certain trunk timer values to be changed on a per-trunk basis or for all
trunks.
You are advised not to change these values (with the exception of trunk
Flash Time) without assistance from Technical Support.
TIMER RANGE
DEFAULT
ANS.BAK TM
0100–2500 MSEC
0600 MSEC
CLEARING
0100–2500 MSEC
2000 MSEC
CO SUPV TM
0100–2500 MSEC
0400 MSEC
DTMF DURATION
0100–2500 MSEC
0100 MSEC
FIRST DGT DELAY
0100–2500 MSEC
0600 MSEC
FLASH TIME
0100–2500 MSEC
0090 MSEC
NO RING TM
01–25 SEC
04 SEC
PAUSE TIME
01–25 SEC
03 SEC
PRS DET TM
0000–2500 MSEC
0000 MSEC
RNG DET.TM
0010–2500 MSEC
0050 MSEC
WINK TIME
0100–0300 MSEC
200 MSEC
MF/DP INT TM
0100–9900 MSEC
0800 MSEC
MFR DLY TM
00–25 SEC
00 SEC
ACTION DISPLAY
1. Open programming and select
503
Display shows
[701] ANS.BAK TM
0600 MS
→
2. Dial trunk number (e.g., 704)
OR
Press VOLUME keys to select trunk and
press RIGHT soft key to move cursor
OR
Select all trunks
[704] ANS.BAK TM
0600 MS
→
OR
[ALL] ANS.BAK TM
0600 MS
→
3. Dial timer number from above list
OR
Press VOLUME keys to select timer and press
RIGHT soft key to move cursor
[704] DTMF DUR.
0600 MS
→
_
4. Enter new timer value (must be same number of
digits as current value, e.g., 0700)
System returns to step 2
[704] DTMF DUR.
0600 MS
→
0700
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next MMC
Default Data:
See table above
Related Items:
None