SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 311 (Page 1 of 2)
MMC: 311
ASSIGN SIM PARAMETER
FOR:
DCS only
Purpose:
Assigns and sets parameters for the serial interface module (SIM). Refer to
Tables 1–12, below.
ACTION
DISPLAY
1. Open programming and select
311
Display shows
[256] SIM PARA
SIM TYPE :DTE
2. Enter station number connected to SIM (e.g., 257)
from dial keypad
OR
Press VOLUME keys to make selection and press
RIGHT soft key to move cursor
[257] SIM PARA.
SIM TYPE :DTE
3. Enter desired selection from table 1 (00–10, e.g.
01)
OR
Press VOLUME keys to make selection and press
RIGHT soft key to move cursor
[257] SIM PARA.
CALL MODE:AWITH
Refer to Table 1 for your selected option and go to
the table indicated (e.g. Table 3) to enter required
value (e.g. 0) using dial keypad or by pressing
VOLUME keys
Press RIGHT soft key to move cursor
[257] SIM PARA.
CALL MODE:MANUAL
4. Repeat step 3 for all required options (00–10 in
Table 1)
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
TABLE 1. SIM PARAMETER
00
SIM TYPE
=
Table 2
01
CALL MODE
=
Table 3
02
ANS MODE
=
Table 4
03
AUTO BAUD
=
Table 5
04
DTR CHECK
=
Table 6
05 ECHO
= Table
7
06 PROTOCOL = Table
8
07 SPEED
= Table
9
08
CHAR LENGTH =
Table 10
09 PARITY
= Table
11
10
STOP BIT
=
Table 12