SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 804 (Page 3 of 3)
ACTION
DISPLAY
1. Open programming and select
804
Display shows
SYS I/O PORT (1)
SERVICE:PC-MMC
2. Enter port number (e.g. 2)
OR
Press VOLUME keys to make selection and press
RIGHT soft key to move cursor
SYS I/O PORT (2)
SERVICE:SMDR
3. Enter parameter option from the above option list
(e.g. 1)
OR
Press VOLUME keys to make selection and press
RIGHT soft key to move cursor
SYS I/O PORT (2)
BAUD:9600 BPS
4. Enter desired value (e.g. 19200 bps)
OR
Press VOLUME keys to display value and press
RIGHT soft key to return to step 2
SYS I/O PORT (2)
BAUD:19200 BPS
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Option
DCS/CII/816
408/408i
i
DCS500
i
DCS100
OS500
Service Type
1 PCMMC
2 SMDR
1 SMDR
1 PCMMC
2 SMDR
3 (to 5) NOT USED
1 PCMMC
2 SMDR
3 NOT USED
2 PCMMC
3 SMDR
5 NOT USED
Baud Rate (bps)
9600
9600
19200
19200
19200
Char Length (bits)
8
8
8
8
8
Parity None
None
None None
None
Retry Count
03
03
03
03
03
Stop Bit
1
1
1
1
1
Wait Time (msec)
3000
3000
3000
3000
3000
DSR Check
Off (not DCS)
Off
Off
Off
Off
SIM Pair
None (DCS)
–
–
–
–
Related Items:
MMC 725 SMDR Options