SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 851 (Page 2 of 5)
Procedure to Print or Clear Alarms
ACTION
DISPLAY
1. Open programming and select
851
Display shows
SYS ALARM REPORT
VIEW ALARMS
2. Press VOLUME keys to select CLEAR or PRINT
SYS ALARM REPORT
CLEAR ALARM BUF
3. Press RIGHT soft key
SYS ALARM REPORT
ARE YOU SURE:NO
4. Press VOLUME keys to select YES/NO and press
RIGHT soft key
SYS ALARM REPORT
ARE YOU SURE:YES
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Alarm Buffer Overwritten
Related Items:
MMC 852 Assign System Alarms
ALARM CODE TABLE
(Your system may not support all the codes listed here.)
ALM CODE
ALARM
DEFINITION
MJA01 POR
Restart
MCP restart process has been executed via power on restart
(POR).
MJA02
Soft Restart
MCP restart process has been executed via button reset.
MJA03 Mem
Reset
The system RAM has been cleared via manual programming
(PCMMC or KMMC) resulting in a system reset.
MJA04 MCP
Reset
The MCP has reset.
Alarm data = Reason
- BUS ERR: Restart Bus Error
- ADDR.ERR: Restart Address Error
- ILLEGAL: Restart Illegal opcode
- ZERO DIVID: Restart Zero divide
- PRIVILEGE: Restart Privilege Violation
- VECTOR 1: Restart Auto Vector Level 1
- DTACK RD: Restart Auto Vector Level 2
- DTACK WR: Restart Auto Vector Level 3
- VECTOR 4: Restart Auto Vector Level 4
- VECTOR 5: Restart Auto Vector Level 5
- VECTOR 6: Restart Auto Vector Level 6
- WR PROTECT: Restart Auto Vector Level 7
- ENDL LOOP: Restart Endless Loop
MJA05 LCP
Reset
The SCP or LCP has reset
Alarm data = Cabinet (1, 2 or 3)
MJB02
Memory Alarm 1
A RAM diagnostic check error has occurred in the MCP.
MJB03
Memory Alarm 2
A RAM diagnostic check error has occurred in the SCP.
MJB04
Memory Alarm 3
A RAM diagnostic check error has occurred in the LCP1.
MJB05
Memory Alarm 4
A RAM diagnostic check error has occurred in the LCP2.