SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 509 (Page 1 of 2)
MMC: 509
C.O. TONE CADENCE
FOR: CI only
Purpose:
Allows customising of the tone cadence provided from the analogue trunk on a
system-wide basis. There are three types of tone available (see below). The control of
the tone cadence may be changed from interrupt tone to continuous tone. Some systems
may require default settings to comply with local operating companies. These tones are
mainly used for performing Automatic Redial depending on call progress tones on re-
quest from internal users on a trunk call.
Once busy tone is detected from the Central Office, the call is automatically released and
is queued for redial after expiration of the Auto Redial Interval timer (see
FEATURE KEYS
DIAL 0
INTERRUPT TONE
DIAL 1
CONTINUOUS TONE
TONES
BUSY TONE
RINGBACK
TONE
DIAL
TONE
ACTION
DISPLAY
1. Open programming and select
509
Display shows
CO BUSY TONE
INTERRUPT TONE
2. Press VOLUME keys to select tone
Press LEFT soft key and advance to step 3
CO RGBACK TONE
CONTINUOUS TONE
3. Dial 0 for INTERRUPT tone or 1 for CONTINUOUS
tone
OR
Press VOLUME keys to select and press RIGHT
soft key
CO RGBACK TONE
INTERRUPT TONE
4. If you selected INTERRUPT tone, dial in new
value(s) for interrupt times (must be four digits
each: sequence on/off/on/off)
Press RIGHT soft key to advance cursor
Press LEFT soft key to retreat cursor
System returns to step 2
CO RGBACK T : 0400
0200 0400 0200
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC