SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 837 (Page 2 of 2 )
Dial Parameter
Description
Default
28 SIP SERVER
PORT
Sets the port number of the SIP Server.
05060
29 SIGNAL PORT Sets the IP UDP port number for signalling.
10000
32 SEND CLIP
TABLE
Sets the table number programmed in
that will be sent
as caller information when calling through the VoIP network. If set
as ‘None’ the number programmed in
is used.
1
33 INCOMING
MODE
For VoIP incoming calls, sets whether to use the received called
party number, or to follow
, or to use the destination
specified for each C.O. line in
Follow DID
Trans
34 ALLOW
GW
CHECK
Allows Gateway IP check.
DISABLE
ACTION
DISPLAY
1. Open programming and select
837
Display shows
GATEWAY CALL ID
1234
2. Dial option number 00–34
OR
Press VOLUME keys to select and press RIGHT
soft key
GATEWAY CALL ID
1234
3. Enter parameter value or press VOLUME keys to
select, as required
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data: See table above.