SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 741 (Page 1 of 1)
MMC: 741
BSI CARD RESTART
FOR: DCS CI CII
i
DCS100
i
DCS500
OS500
Purpose
: Restarts a BSI card or DECT base station (DBS). The DBS/BSI card will be
restarted automatically.
ACTION
DISPLAY
1. Open programming and select
741
Display shows
BSI SLOT : 1 DBS : 1
RESTART ? NO
2. Select the specific BSI slot number (or press the
RIGHT soft key and select the specific DBS)
using the keypad or the VOLUME keys
OR
Select all DBS
Press the RIGHT soft key
BSI SLOT : 2 DBS : 1
RESTART ? NO
3. Press VOLUME keys to select YES or NO and
press RIGHT soft key
BSI SLOT : 2 DBS : 1
RESTART ? YES
4. Confirm whether you want to restart by selecting
YES or NO using the VOLUME keys, and press
RIGHT soft key
BSI SLOT : 2 DBS : 1
ARE YOU SURE ? YES
5. Press Transfer/TRSF to exit
OR
Press SPEAKER to advance to next MMC
Default Data:
None
Related Items:
MMC 737 DECT System Code
MMC 738 DECT Clear Registration
MMC 739 BSI Download
MMC 742 BSI Status
MMC 743 DBS Status
MMC 744 DECT Registration On/Off
MMC 745 BSI Carrier