SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 219 (Page 1 of 1)
MMC: 219
COMMON RELAY
SERVICE TYPE
FOR: CII
816
408
408i
i
DCS100
Purpose:
Defines the function of the common relays.
Compact II and
i
DCS100:
The three common relays in the Misc card (363–365)
816:
The common relay in the base board (362)
408/408i:
The common relay in the base board (361).
Each relay can be used for one of the following:
0
EXTERNAL PAGE
1 COMMON
BELL
2 LOUD
BELL
3 NOT
USED
ACTION
DISPLAY
1. Open programming and select
219
Display shows (e.g. 363)
[363]RELAY TYPE
EXTERNAL PAGE
2.
Compact II &
i
DCS100 only
– dial relay number
(e.g. 364)
OR
Press VOLUME keys to scroll through numbers
and press RIGHT soft key to move cursor
816/408/408i
– press RIGHT soft key to move
cursor
[364]RELAY TYPE
EXTERNAL PAGE
3. Dial relay function 0–3 (e.g. 2–see table above)
OR
Press VOLUME keys to scroll through options
and press RIGHT soft key
[364]RELAY TYPE
LOUD BELL
4.
Compact II &
i
DCS100 only
– repeat step 2 for
next relay
[364]RELAY TYPE
NOT USE
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
EXTERNAL PAGE
Related Items:
MMC 203 Assign UA Device
MMC 204 Common Bell Control
MMC 205 Assign Loud Bell
MMC 601 Assign Station Group
MMC 605 Assign External Page Zone