Configuration Guide
SNMP Configuration
The keywords
―0‖ and ―7‖ indicate encryption type of community string. If the
keyword
―0‖ is used before the community string, it indicates the input
community name is plaintext. If the keyword
―7‖ is used, it indicates the input
community name is ciphertext. If the option is not specified, ciphertext is used
for
community
name
by
default.
After
configuring
the
service
password-encryption
command, the community string is displayed and
recorded in cipher. If you then configure
no
service password-encryption
, the
community string is still displayed and recorded in cipher but not plaintext.
Configuring SNMP Protocol Port
By default, the SNMP protocol uses 161 UDP port to receive SNMP messages;
Because of security concerns, users can define which UDP port is used.
To configure the SNMP protocol port number, run the following command in
global configuration mode.
Command
Function
Ruijie(config)#
snmp-server udp-port
port-num
Specify a UDP port for SNMP to receive
messages.
Use the
no snmp-server udp-port
command to restore the default port.
Configuring MIB Views and Groups
With view-based access control model, you can determine whether the object of
a management operation is in a view or not. For access control, generally some
users are associated with a group and then the group is associated with a view.
The users in a group have the same access right.
Set an inclusion view and an exclusion view.
Set a Read-only view and a Read-write view for a group.
Set security levels, whether to authenticate, and whether to encrypt for
SNMPv3 users.
To configure the MIB views and groups, run the following commands in the
global configuration mode:
Command
Function
Ruijie(config)#
snmp-server view
view-name oid-tree
{
include | exclude
}
Create a MIB view to include or exclude
associated MIB objects.
Ruijie(config)#
snmp-server group
groupname
{
v1
|
v2c
|
v3
{
auth
|
noauth
|
priv
}} [
read
readview
] [
write
writeview
]
Create a group and associate it with the
view.
You can delete a view by using the
no snmp-server view
view-name
command, or delete a tree from the view by using the
no
snmp-server view
Summary of Contents for RG-S2900G-E Series
Page 1: ...RG S2900G E Series Switch RGOS Configuration Guide Release 10 4 2b12 p1 ...
Page 91: ...Configuration Guide Configuring PoE Configuration ...
Page 133: ...Configuration Guide EEE Configuration ...
Page 319: ...Configuration Guide QinQ Configuration ...
Page 408: ......
Page 409: ...IP Routing Configuration 1 Static Route Configuration ...
Page 412: ......
Page 413: ...Multicast Configuration 1 IGMP Snooping Configuration 2 MLD Snooping Configuration ...
Page 757: ......
Page 758: ...ACL QoS Configuration 1 Access Control List Configuration 2 QoS Configuration ...
Page 801: ...Reliability Configuration 1 RLDP Configuration 2 TPP Configuration 3 SEM Configuration ...
Page 901: ...Configuration Guide ERSPAN Configuration ...
Page 902: ...Web based Configuration 1 Web based Configuration ...