background image

ZigBee

TM

-Wall Switch

User Manual

Two Channel Wall Switch

Model: Z815B

Energy Consumption Monitoring Series

Firmware: V3.2

Hardware: V1.2

For Home Automation

20110423

20120803

Summary of Contents for ZigBee Z815B

Page 1: ...ZigBeeTM Wall Switch User Manual Two Channel Wall Switch Model Z815B Energy Consumption Monitoring Series Firmware V3 2 Hardware V1 2 For Home Automation 20120803 ...

Page 2: ...Network Indicator Switch 1 indicator Switch 2 indicator Binding key L out2 L out1 L in N ...

Page 3: ...Bee is based on IEEE802 15 4 standard the mutual co ordination between thousands of sensors to exchange data Sensor to sensor or node to node communication is achieved through relays of control data between devices with only a fraction of energy use which denoted for highly transmission efficiency Note Wireless communication in some real use cases can be limited by the signal blockage Please consu...

Page 4: ...outer in the network Step 2 Now connect AC power cable to power it Z815B device will start to search for the network within reach Notice If the network indicator stays solid lit in the beginning this indicates that Z815B has previously joined to a network If so please clear the setting stored in the device Refer to Restore to factory setting section of the manual Step 3 if joining is in process th...

Page 5: ...or twice for Switch_2 pairing LED flash twice Z815B will sent out pairing request to the air 2 Likewise do the same to the other device to exchange binding refer to the other device user manual for device pairing procedure When binding is successful the indicator on Z815B will slow flash 5 times otherwise quick flashes 10 times indicating pairing unsuccessful If successful you should be able to wi...

Page 6: ...adings to a paired target device normally are an in home display or consumption data logger Ensure that you go through consumption reporting and configure reporting time interval described in ZiG BUTLER page otherwise Z815B will not sent consumption reading Z815B can report the consumption reading to Netvox s ZiG BUTLER or to any 3rd party in home display Power drawn overtime is measured Current u...

Page 7: ...eading In some cases user would wish to return the counter to zero Same feature can be found in ZiG BUTLER software with the Recalculate button Operation Hold press binding key for 20 seconds or so until the indicator flashes once then release the key then within 2 seconds short press any switch button once If successful the indicator will flash once Restore to factory setting Z815B is capable of ...

Page 8: ...hold press binding key Flashes quickly switch button once Permit Join Short press binding key once Flashes 60 times in 60 seconds Resetting power consumption summation Hold press binding key 20s then within 2s short press control button once Flashes once hold press binding key Flashes once switch button once Device Pairing Hold press binding key 3s Within 5s press again once or twice for the butto...

Page 9: ...outage happened or Off at power restoration The device is set to one of these statuses at factory level You can tell us which default setting at the time of purchase order Loading Property Rated Load AC Remark Max Load with LEDs Remark Max Inductive Load cosφ 0 4 Max Load with Electric Motors Max Surge Endurable Surge Detecion Overload Protection with Auto Power Cutoff 10A 250V 400W 8 LEDs for eac...

Page 10: ...0005 On Off 0x0006 Meter 0x0702 endpoint 1 Netvox Proprietary Commissioning 0015 Attributes of the Basic Information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion 8 bit Unsigned integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion 8 bit Unsigned integer 0x00 0xff Read only 0x0A O 0x0002 StackVersion 8 bit Unsigned integer 0x00 0xff Read only 0x2D O 0x0003 H...

Page 11: ...Identifier Name Type Range Access Default Mandatory Optional 0x0006 DateCode Character string 0 16 bytes Read only 20120215 O 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x01 M ...

Page 12: ...Z815B is within the network and receives command from the network no problem How to enable permit join please refer to any ZigBee router device for such feature Test 3 If test 1 and 2 items are found working then what was left is device pairing between Z815B and the control device Please refer to Step 2 Device pairing binding of this user manual Please keep in mind that when device pairing is done...

Page 13: ...n a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electronic par...

Page 14: ...x is not responsible for data or revenue loss or any indirect additional loss that may arise from special cases or any sudden obligations This documentation is provided according to the product at the time of purchase Netvox do not inherent any responsibility and promise or guarantee of the reliability of the document contents this applies but not limited to market piloting or real use case purpos...

Reviews: