INDEX
IMR01N12-E7
B-3
Required operations and functions
Control panel needs to be designed and fabricated.
Dimensions ...................................................................... 11
Wiring ............................................................................... 13
Terminal Layout ............................................................... 14
Wiring of Each Terminal................................................... 15
The accessory, Model code and specification of this
controller need to be checked.
Checking the Product ......................................................... 1
Model Code ........................................................................ 2
Specifications ............................................................... A-24
This controller needs to be installed and wired.
Mounting .........................................................................
10
Wiring ............................................................................... 13
Specifications ............................................................... A-24
Basic key operation needs to be checked.
Parts Description ................................................................ 7
Key Operation .................................................................. 26
Changing Parameter Settings .......................................... 28
Initial settings need to be made before operation.
Check of the setting procedure
Setting Procedure to Operation ....................................... 22
Operation Menu ............................................................... 24
Check of the parameters for controller’s basic functions
(Engineering
mode)
Input type selection .......................................................... 66
Display unit selection ....................................................... 67
Gain setting ...................................................................... 67
Linearize type selection ................................................... 68
Shunt resistance output value ......................................... 68
Power supply frequency selection ................................... 72
Output logic selection ....................................................... 76
Control action type selection ............................................ 87
Setup data setting
SETUP SETTING MODE ................................................ 42
Check of the parameter and SV
PARAMETER SETTING MODE ...................................... 32
SV SETTING & MONITOR MODE .................................. 30
Set value (SV) needs to be changed.
Changing Parameter Settings .......................................... 28
Set value (SV1) setting .................................................... 30
Set value (SV2) setting .................................................... 30
Direct key operation needs to be restricted.
Direct Key (F11) ............................................................. 65
RUN/STOP needs to be switched.
Configuration of Operation Mode ................................... 101
RUN/STOP Transfer ...................................................... 112
Autotuning needs to be started (suspended).
Configuration of Operation Mode ................................... 101
AT action .......................................................................... 96
Autotuning (AT) function .................................................. 96
Auto/Manual needs to be switched.
Configuration of Operation Mode .................................. 101
Auto/Manual Transfer .................................................... 108
Remote/Local needs to be switched.
Configuration of Operation Mode .................................. 101
Remote/Local Transfer .................................................. 111
Parameter change due to misoperation needs to be
prevented.
Set lock level ................................................................... 49
Manipulated output value (MV) under Manual control
needs to be manually set.
Procedure for setting the manipulated output value (MV)
in Manual mode ............................................................. 110
Control area needs to be changed.
Control Area Transfer .................................................... 114
The setting range of high and low limit values needs
to be changed.
Setting limiter low ............................................................ 98
Setting limiter high ........................................................... 98
The scale range of the input range needs to be
changed.
Decimal point position ..................................................... 69
Input scale high ............................................................. 69
Input scale low ................................................................. 70
Event (EV1 to EV4)
Event output destination needs to be changed.
Output logic selection (LoGC) ......................................... 76
The condition of alarm lamp lighting needs to be
changed.
Alarm lamp lighting condition setting (ALC1) .................. 77
Event action type needs to be changed.
Event type selection (ES1 to ES4) .................................. 80
Event hold action (EHo1 to EHo4) .................................. 82
Event differential gap (EH1 to EH4) .............................. 83
Input subject to event judgment needs to be changed.
Event assignment (EVA1 to EVA4) ............................... 84
The assignment of event input (DI) needs to be
changed.
Event input logic selection (dISL) .................................. 73
Interlock needs to be activated (or released).
Interlock function ............................................................. 78
Interlock release ...................................................... 30, 106
The content of transmission output needs to be
changed.
Transmission output type selection ................................. 79
Display position of STOP characters during control
STOP needs to be changed.
STOP display selection ................................................... 63