7. SETUP SETTING MODE
46
IMR01N12-E7
Device address (Slave address) (Add2)
Device address is used to set the Slave address of the controller for Communication function (optional).
Data range:
0 to 99 (RKC communication, Modbus)
0 to 63 (DeviceNet)
0 to 64 (CC-Link: 1 station occupied 1 time, 1 station occupied 4 times, 1 station occupied 8 times)
0 to 126 (PROFIBUS)
1 to 61 (CC-Link: 4 stations occupied 1 time)
Factory set value:
0
Do not use the same device address for more than one controller in multi-drop connection.
Each controller must have a unique address in multi-drop connection.
In Modbus and PROFIBUS and CC-Link communications, two-way communications are not
possible when the addresses are 0.
Communication speed (bPS2)
Communication speed is to set communication speed for Communication function (optional).
Data range:
2.4: 2400 bps
125: 125 kbps
1
156:
156
kbps
2
4.8: 4800 bps
250: 250 kbps
1
625:
625
kbps
2
9.6: 9600 bps
500: 500 kbps
1
2500:
2.5
Mbps
2
19.2: 19200 bps
5000: 5 Mbps
2
38.4: 38400 bps
10000: 10 Mbps
2
1
A communication speed of 125 to 500 kbps can be selected for DeviceNet.
2
A communication speed of 156 kbps, 625 kbps, and 2.5 to 10 Mbps can be selected for CC-Link.
Factory set value:
9.6 (RKC communication, Modbus)
125
(DeviceNet)
156
(CC-Link)
Set the same communication speed for both the HA430/930 (slave) and the host computer (master).
Communication speed is not necessary to be selected for PROFIBUS.
Data bit configuration (bIT2)
This item is Data bit configuration of Communication function (optional).
Data range:
Refer
to
below
[
Data bit configuration table
]
Set value
Data bit
Parity bit
Stop bit
(8n1)
8
Without
1
(8n2)
8
Without
2
(8E1)
8
Even
1
(8E2)
8
Even
2
(8o1)
8
Odd
1
(8o2)
8
Odd
2
(7n1)
*
7
Without
1
(7n2)
*
7
Without
2
(7E1)
*
7
Even
1
(7E2)
*
7
Even
2
(7o1)
*
7
Odd
1
(7o2)
*
7
Odd
2
* When the Modbus communication protocol selected, this setting becomes invalid.
Factory set value:
8n1 (Data bit: 8, Parity bit: Without, Stop bit: 1)
Data bit configuration is not necessary to be selected for PROFIBUS, DeviceNet and CC-Link.
Setting range of
RKC communication
Setting range
of Modbus