APPENDIX
A-
IMR01N12-E7
8
Function block F21: Input 1
Name Parameter Data
range
Factory set
value
User set
value
Page
Input 1_input type selection
(1. InP)
Voltage (V)/Current (I) inputs
19999 to
99999
14: 0 to 20 mA DC 24:
±
100 mV DC
15: 4 to 20 mA DC 25:
±
10 mV DC
16: 0 to 10 V DC
26:
±
10 V DC
17: 0 to 5 V DC
27:
±
5 V DC
18: 1 to 5 V DC
28:
±
1 V DC
19: 0 to 1 V DC
20: 0 to 100 mV DC
21: 0 to 10 mV DC
Pressure sensor input
0.0 to 250.0 MPa
29: Resin pressure sensor
Relevant pressure sensors:
CZ-100P,
CZ-200P
22, 23: Unused (Not available)
Based on
model code.
When not
specifying:
Pressure sensor
input
P.
66
Input 1_display unit selection
(1.UnIT)
2: MPa
3: bar
4: kgf/cm
2
5: psi
The display unit selection becomes
invalidated when the Voltage (V)/
Current (I) input is selected as input
type.
Pressure sensor
input: 2
V/I: 0
P.
67
Gain setting
(GAIn)
0.500 to 4.000 mV/V
Relevant pressure sensors:
CZ-100P,
CZ-200P
CZ-100P, CZ-200P:
1.500
P.
67
Linearize type selection
(LInS)
0: Unused
1 to 20: Used
*
Relevant pressure sensors:
CZ-100P,
CZ-200P
0
P.
68
Shunt resistance output value
(SHnT)
40.0 to 100.0 %
80.0
P.
68
*
Linearizing type:
Set value
1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
16
17
18
19
20
Symbol
C D E F G H J K
L M
P Q
R
S T U V W X
Y
Continued on the next page.