Engineer Programming
Page 50
Chapter 4 Engineer Programming
Programming Methods
Program the LightSYS through one of three methods:
Configuration Software (Local or remote)
Program Transfer Module
(
PTM)
LCD Keypad
Configuration Software
A software application that enables you to program the LightSYS from a PC computer. It
offers the following alternatives:
Working locally, through a portable computer connected to the LightSYS via cable
Working at a remote site, communicating with the LightSYS via one of the
following options:
o
A phone line and modem
o
TCP/IP network using the IP Module
o
GPRS using the GSM/GPRS communication module
For further information on programming the LightSYS via the Configuration Software, refer
to the
Configuration Software
manual.
PTM: Data Storing Device
The PTM is a tiny circuit board into which the LightSYS panel can transmit a copy of the
system's configuration. The PTM stores this copy and can also transmit the configuration
information back to the LightSYS panel.
To copy from a programmed main panel into the PTM:
1.
Position the PTM on PLUG 1 connector on the main panel with the red LED facing
the row of terminals on the main panel. The red LED flashes slowly.
2.
Position the default DIP switch 2 to the ON position.
Note:
The DIP2 should be software enabled (Engineer programming Quick key 1 5 1)
3.
From an LCD keypad, access the main Engineer Programming menu.
4.
Without making any changes, exit the main Engineer Programming menu by
pressing [0]. The LED on the Program Transfer module flashes rapidly, and the
keypad displays the following:
Saving data in
PTM Accessory
5.
When the LED stops flashing rapidly, the keypad beeps twice and displays the
following:
Data is saved