Bus Expander
The BUS Zone Expander enables to expand the number of BUS detectors
connected to the LightSYS to 32. Up to 4 Buz expanders can be defined.
Each BUS Zone Expander creates a separate BUS loop that is used only
for the BUS detectors connected to it. The separate BUS loop increases
the total system security in case a certain BUS detector is sabotaged.
To specify and configure Bus expander
1.
Through the menu selection, the following display appears:
BUS Expander:
TYPE=NONE
2.
With the cursor positioned at the
TYPE
field, use the
key
to toggle and choose the
BZE32
option
3.
Press
to store your choice
LRT (Long Range Transmitter)
To specify and configure LRT
1.
Through the menu selection, the following display appears:
LRT Module:
TYPE=NONE
2.
With the cursor positioned at the
TYPE
field, use the
key
to toggle and choose the
MAT
option
3.
Press
to store your choice
Bus Devices: Testing
Quick Keys
Parameter
Default
Range
Testing
The testing menu is used to perform system bus and module testing,
scanning and verification functions