Engineer Programming
Page
91
Quick Keys
Parameter
Default
Range
If violated, it causes an immediate fire alarm, and the Fire/
LED is
lit (steady).
A fault in the wiring (wire open) to any fire zone causes a Fire Fault
signal (a rapid flashing of the keypads' FIRE /
LED). A short in the
wires will cause an immediate alarm.
ZZ
Panic
Used for external panic buttons and wireless panic transmitters.
If violated, an immediate panic alarm is sounded (if the zone sound is
not defined as silent or audible panic system control is enabled),
regardless of the system’s state and panic report is sent to the alarm
receiving centre. An alarm display will not appear on the keypads.
If violated, an immediate panic alarm is sounded, regardless of the
system's state.
ZZ
Special
For external auxiliary emergency alert buttons and wireless auxiliary
emergency transmitters.
If violated, an immediate auxiliary emergency alarm is sounded,
regardless of the system’s state and a report is sent to the alarm receiving
centre.
ZZ
Pulsed Key Switch
Used to set/Unset the system.
Connects an external momentary action keyswitch to any zone terminals
given this designation.
ZZ
Final Exit
Zones of this type must be the last detector to be activated on exit or the
first detector to be activated on entry. When arming the system, the
related partition sets 10 seconds after this zone is closed, or opened and
then closed. After it is triggered once, the zone acts as an exit
(open)/entry 1 zone.
ZZ
Latch Keyswitch
Connect an external SPST latched (non-momentary) keyswitch to any
zone terminals given this designation and operate the keyswitch, as
follows:
After setting one or more partitions using the keyswitch and then