Engineer Programming
Page 138
Quick Keys
Parameter
Default
Range
Periodic Test
00
HR: 00–96
MIN 00–59
The Periodic Test enables you to set how often the system will
automatically establish communication to the alarm receiving centre in
order to confirm operational functionality. The periodic test involves
sending the account number and a valid test report code (Contact ID
602).
No. Comm. Parameter
060
0-255
Specify the timeout threshold for establishing communication between
the LRT and bus, which upon being reached, triggers an event report to
the alarm receiving centre.
Control
060
0-255
Disable Low Battery
Y
Yes/No
YES
: [For use when LRT is housed in the main LightSYS box] LRT low
battery fault condition will not be regarded.
NO
: [For use when LRT is housed remotely in its own box] LRT low
battery fault condition will be regarded.
Alarm Receiving Centre
The Alarm Receiving Centre menu contains parameters that enable the system to establish
communication with the (up to three) alarm receiving centres and transmit data.
Quick Keys
Parameter
Default
Range
Report Type
Defines the communication type that the system will establish with each
alarm receiving centre. The system can report in three optional
communication channels:
Voice
IP
SMS
LRT