Engineer Programming
Page 54
10.
Move to the section "Identifying the connected devices" as described below.
Regular operation mode
To enter Engineer Programming mode
1.
From the main display press
.
2.
Enter the Engineer code (default:
) and press
.
3.
Select
[1] Programming
and press
.
4.
You are now in Engineer Programming mode. Move to the section "
Identifying
the connected devices
" described below
Identifying the Connected Devices
Automatic Setting
Note:
By default, when entering Engineer mode with the default DIP Switch 2 in ON position,
the system will take you immediately to Auto Settings. If the keypad is already
showing BUS SCANNING, skip to step 2 below.
1.
Enter the programming key sequence
(
Install, BUS Devices,
Automatic
).
2.
Press
to begin the automatic
BUS SCANNING
(the Auto Settings process) in
which it identifies all the devices on the bus.
3.
Verify that the keypad displays all the devices you have connected. If a device does
not appear, ensure that you have given it a unique ID within its “family”.
4.
Press
to accept what is being displayed, to progress through configuration
screens and to advance on to the next device found.
5.
Repeat steps 3 and 4 until the presence of all devices has been confirmed and all
parameters configured.
Notes:
When adding a zone expander you should define the zones expander resistance
compatibility, depending on the detectors you intend to connect to the expander. By
default the resistance is set to 2.2K for EOL and DEOL termination.
When adding a wireless expander, define the “
Omit Box Tamper
” as YES if the
wireless expander is mounted inside the LightSYS housing and not in its own.