Quick Keys
Parameter
Default
Range
Audible Jamming
No
Yes/No
Relates to the
Jamming Time
parameter, described on page 62
YES
:
Once the specified time is reached, the Main Panel activates any
internal sounders and sends a Report Code to the ARC
.
NO
: Same as above, except the internal sounders do not operate.
Exit Beeps at Part Set
Yes
Yes/No
Determines whether the system will sound beeps during exit time in
part set arming.
YES
: Exit beeps will sound
.
NO
: Exit beeps will not sound.
Forced Keyswitch
Arming
Yes
Yes/No
YES:
Keyswitch or Proximity Key arming is performed on any partition.
Any violated (not READY) zone(s) in the partition will be omitted
automatically. The partition is then "force set," and all intact zones are
capable of producing an alarm.
NO
: The partition cannot be set until all violated (not ready) zones are
secured.
Set Pre-Warning
Yes
Yes/No
Related to auto set/unset operation.
YES
: For any partition(s) set up for auto arming, an audible exit delay
(warning) countdown will commence 4.25 minutes prior to the
automatic arming. During this period, exit delay beeps will be heard.
You can enter a valid user code at any time during the countdown to
delay the partition’s automatic arming by 45 minutes.
When an “Auto-Set” partition is unset, as described above, it can no
longer be automatically set during the current day.
The extended 4.25 minutes warning does not apply to automatic partial
arming.
NO
: Auto arming for any programmed partition(s) takes place at the
designated time. The programmed exit delay period and any audible
signal occur as expected.