Engineer Programming
Page
99
Bus Zone: iWISE DT Grade 2
Quick Keys
Parameter
Default
Range
ZZ
LEDS
On
Defines the LEDS operation mode.
OFF
- Disables the LEDS operation.
ON
– Enables the LEDS operation.
ZZ
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
MINIMUM
25%
50%
65%
85%
MAXIMUM
TRIMMER
(MW is defined by the trimmer setting on the PCB)
ZZ
ACT
No
Defines the Anti-Cloak™ Technology (ACT) operation mode.
NO
– Disables the ACT mode
YES
– Enables the ACT mode
ZZ
Automatic Microwave Omit
No
Defines whether the MW channel will be omitted or not while the
detector identifies fault in the MW channel.
NO
- While detecting a problem in the MW channel it is not omitted.
Alarm condition cannot be established until the MW channel is fixed.
YES
- Switches the detector to operate only in PIR mode in case of
MW fault
ZZ
Green Line
Yes
A feature that follows environmental guidelines by avoiding surplus
emission This feature defines the activation of the microwave channel
while the system is unset.
NO
- Green Line feature is disabled. MW is constantly activated.
YES
- Green Line feature is activated.
ZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Fault is created.
REMOTE
(Manual) - The remote self test is performed by the system
when a user manually selects the Diagnostics option from the
Maintenance menu via the LightSYS User Functions menu
LOCAL
(automatic) - Once an hour, the detector automatically checks
that the detector’s channels are functioning properly.