Programmable output: Pattern of Operation
Quick Keys
Parameter
Default
Range
Pulse N/C
05 seconds
01-90 seconds
The programmable output is always activated (N/C) before it is
triggered (pulled down to negative).
When triggered, it deactivates for the pulse duration specified below
and then reactivates automatically.
1.
Press
and then press
.
2.
Choose the desired pulse duration, between 01-90 seconds.
3.
Press
and set the activation by choosing ALL or ANY using
the
key.
4.
Press
and define a label for the PO (refer to the note below).
Latch N/C
The programmable output is always Activated (N/C) before it is
triggered (pulled down to negative). When triggered, it deactivates
and remains deactivated (latched) until the operation is restored.
1.
Press
and then press
.
2.
Using the
key select ALL or ANY to set the activation and
press
.
3.
Using the
key select ALL or ANY to set the deactivation and
press
.
4.
Define the output label and press
Pulse N/O
05 seconds
01-90 seconds
The programmable output is always deactivated (N/O) before it is
triggered (pulled up). When triggered, it activates (is pulled down)
for the pulse duration specified below, then deactivates automatically.
1.
Press
and then press
.
2.
Choose the desired pulse duration, between 01-90 seconds
3.
Press
and set the activation by choosing ALL or ANY using
the
key
4.
Select a label for the PO (refer to the note below).