Engineer Programming
Page 114
Follow Partition
The Partition menu contains Programmable output parameters that follow the
Partition Event. The Programmable output can follow any partition(s) combination
To access the Partition sub-menus:
1.
Access the Outputs menu, as described on page 110.
2.
From the Programmable output menu press
.
The following display appears:
:
PO=01 FOLLOWS:
2) PARTITION
3.
Press
to access the Partition menu options. The following display appears:
PAR.EVENT: PO=01
01)READY FOLLOW
4.
Select the partition event to be followed from those listed below, using the
/
keys.
Quick Keys
Parameter
Ready Follow
Activates the output when all the selected partition(s) are in the
READY
state.
Alarm Follow
Activates the output when an alarm occurs in the selected partition(s).
Set Follow
Activates the programmable output when the selected partition(s) is set
in either the
FULL SET
or
PART SET
mode. The programmable output
will be activated immediately, regardless of the exit delay time period.
Burglary Follow
Activates the output when an intruder (intrusion) alarm occurs in
the selected partition(s).
Fire Follow
Activates the programmable output when a fire alarm is triggered in
the selected partition(s) from the keypads or a zone defined as Fire
.
Panic Follow
Activates the programmable output when a panic alarm is triggered
in the selected partition(s) from the keypads, remote controls or a
zone defined as Panic