Engineer Programming
Page
101
Quick Keys
Parameter
Default
Range
ZZ
Set/Unset
No
Defines the operation of the anti masking detection while the detector is
set or unset
.
.
NO
– While set or unset, anti-mask behaves according to the setting
defined in quick keys
ZZ
above.
YES
– While set, anti-mask is disabled. When detector is unset Anti-
mask behaves according to the settings defined in quick keys
ZZ
.
ZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Fault is created
REMOTE
(Manual) - The remote self test is performed by the system
when a user manually selects the Diagnostics option from the
Maintenance menu via the LightSYS User Functions menu
LOCAL
(automatic) - Once an hour, the detector automatically checks
that the detector’s channels are functioning properly.
Bus Zone: iWISE QUAD Grade 2
Quick Keys
Parameter
Default
Range
ZZ
LEDS
On
Defines the LEDS operation mode.
OFF
- Disables the LEDS operation.
ON
- Enables the LEDS operation
ZZ
PIR Sensitivity
High
Defines the PIR sensitivity of the detector.
LOW
HIGH
ZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Fault is created
REMOTE
(Manual) - The remote self test is performed by the system
when a user manually selects the Diagnostics option from the
Maintenance menu via the LightSYS User Functions menu
LOCAL
(automatic) - Once an hour, the detector automatically checks
that the detector’s channels are functioning properly