Engineer Programming
Page
177
Keyfob
Quick Keys
Parameter
Default
Range
Keyfob
The keyfob menu defines the operation of the wireless buttons keys. Each
keyfob consists of 4 buttons, and each button can be programmed to
a different mode of operation.
1.
The first step in the menu is to select a user. Each user has a single
keyfob. When selected press .
2.
Select a button (1-4) and define the button operation according to the
options below.
Note
: Each key has its own list of options. The list
varies between the keys.
The available modes of operation are:
None
: Button disabled.
Set
: The button is used for full set arming of the assigned partitions.
Unset:
The button is used for disarming its assigned partitions.
Part Set
:
The button is used for part set (home) arming of the
assigned partitions.
Group:
The button is used for Group arming (Partial arming
within a partition / area) of the assigned partitions
.
PO:
The button is used to operate a single programmable output
Panic:
The button is used to send a panic alarm.
Note:
Full Set or PART SET arming can be defined as instant or delayed (Exit
Delay).
The available options for each button are:
Button 1 (
): None, Set. Part Set, Group, PO
Button 2 (
) : None, Unset, PO
Button 3: None, Set. Part Set, Group, PO, Panic
Button 4: None, Set. Part Set, Group, PO
Sounder
The Sounder menu enables to define all parameters of external sounder that can be connected
to the LightSYS as a bus accessory.
The Sounder menu is divided into the following sub-menus
Parameters
Lamp Times