Engineer Programming
Page 98
To configure the Bus Zone detector parameters:
1.
From the Miscellaneous menu, press [3] to access the Bus Zone parameters menu
options. The following display appears:
2.
Select the zone that the bus zone detector was assigned to and press
. The Bus
Zone parameters menu appears.
3.
Use the below tables to configure the parameters for each Bus Zone detector type.
Bus Zone: OPR12 (WatchOUT PIR)
Quick Keys
Parameter
Default
Range
ZZ
LEDS
3 LEDS
Defines the LEDS operation mode.
OFF
- Disables the LEDS operation.
RED ONLY
- Only the Red LED will operate. This option is highly
recommended to avoid the possibility that an intruder will “Learn” the
detector behavior.
3 LEDS
- All 3 LEDs will operate..
ZZ
PIR Sensitivity
Normal
Defines the PIR sensitivity of the detector.
LOW
MEDIUM
NORMAL
HIGH
ZZ
Lens Type
Wide Angle
Defines the actual lens of the detector.
WIDE ANGLE
BARRIER / LONG RANGE
ZZ
Auxiliary Relay Mode
Off
Defines the operation of the auxiliary relay of the detector.
OFF
- Auxiliary relay is disabled
24 Hours
- The auxiliary relay will always follow an alarm
NIGHT ONLY
- The auxiliary relay output will follow an alarm
condition only during night time. The time defined by the photocell on
the PCB.
ZZ
Auxiliary Relay Time
2.2 Seconds 2.2–480 seconds
Defines the time duration that the auxiliary relay is activated.
2.2 SECONDS
2 MINUTES
4 MINUTES
8 MINUTES