Engineer Programming
Page 74
Quick Keys
Parameter
Default
Range
Part Set Strobe
No
Yes/No
YES
: For Part Set or group arming, a squawk indication will be made by
the strobe activated by an output (Utility output >Follow Partition >
Strobe Trigger) at the end of the exit delay time.
NO
: For Part Set or group setting, no indication will be made by the
strobe at the end of the exit delay time.
Blank display
No
Yes/No
YES
:
Two minutes after the last keypad operation, the display will
appear blank. After pressing any key, an
Enter Code
message will be
displayed. The user should enter his code or pass his proximity tag. The
display returns to the normal operation mode. Select this option for
keypads that can be viewed from outside the protected area to disguise
the system status.
NO
: The keypad display operates normally
System: Controls: Communication
Quick Keys
Parameter
Default
Range
Communication
This section refers to controls of the systems communication capabilities.
Monitoring] Station
Enable
Yes
Yes/No
YES
: Enables communication with the central station to report alarms,
faults, and supervisory events.
NO
: No communication with the central station is possible. Choose NO
for installations that are not monitored by a central station.
Follow Me Enable
Yes
Yes/No
YES
: Enables Follow-Me communication.
If both the ARC report and the FM report are defined, the system will
first call the ARC phones and then the FM destinations.
NO
: Disables Follow-Me communication.