Engineer Programming
Page 116
Quick Keys
Parameter
Bell Follow
This output enables the connection of different external sounders to
different partitions. Activates the output when one of the defined
partitions is in alarm mode and the bell is triggered. It will be activated
for the programmed bell time or until the alarm is unset.
Note:
The external sounder will not generate any squawk sounds
Bell Part Set Off
This parameter causes the output to function as follows:
In
Full Set
arming mode, the output will follow the bell
activation in the defined partitions.
In
Part Set
mode, the output will not be activated.
Notes:
If an alarm occurs in a zone that shares more than one partition and
one of the partitions is in
Set
mode (while the other is in
Part
Set
mode), the output will be activated, as described above.
In
Part Set
mode, a 24-hour zone will not activate this output
.
Zone Omit
Activates the output when the relevant partitions are in
Full Set
or
Part Set
mode and any zone in the relevant partitions is omitted.
Automatic Set Alarm
Activates the programmable output when there is a not ready zone at
the end of the pre warning time during an auto‐set process. The
output restore shall be on Bell‐ Timeout or at user Unset.
Zone Loss Alarm
Activates the programmable output when there is a lost wireless zone
in the system. The output restore shall be on Bell‐Timeout or at user
Unset.