Engineer Programming
Page
113
Quick Keys
Parameter
Installation
Activates the output following the system installation status. It activates
when the system is in engineer programming mode and deactivates
when exiting engineer’s mode.
Walk Test
Activates the output when the “Walk Test” option is selected (see page
185) and deactivates when the “Walk Test” option is finished.
Burglary
Activates the output (Pulsed only) following any intruder activation in
the system (Regardless the bell time out timer). The maximum number
of times an output can be activated from the same zone is defined
according to the Swinger Limit Timer (Quick key
)
Panic
Activates the output (Pulsed only) following any panic activation in the
system. The maximum number of times an output can be activated from
the same zone is defined according to the Swinger Limit Timer (Quick
key
).
Fire
Activates the output (Pulsed only) following any fire activation in the
system. The maximum number of times an output can be activated from
the same zone is defined according to the Swinger Limit Timer (Quick
key
)..
Special
Activates the output (Pulsed only) following any special emergeny
activation in the system. The maximum number of times an output can
be activated from the same zone is defined according to the Swinger
Limit Timer (Quick key
).
24 Hour
Activates the output (Pulsed only) following any 24 Hour zone
activation in the system. The maximum number of times an output can
be activated from the same zone is defined according to the Swinger
Limit Timer (Quick key
).