Engineer Programming
Page 58
COM
BLK
BUS
YEL GRN
AUX
RED
BLK
TO PANEL
RED
YEL GRN
BLK
TO DEVICE
RED
YEL GRN
BLK
TO PANEL
RED
YEL GRN
BLK
TO DEVICE
RED
YEL GRN
LightSYS
BUS Zone Expander
BUS Zone Expander
Max of 32 Bus detectors in LightSYS
...Up to 4 Bus Zone Expanders
...Up to 300m
(1000 ft)
...Up to 300m
(1000 ft)
Step 1: Adding the Bus Expander to LightSYS
Note:
If you already performed Auto Settings skip to Step 2 below: Assign Bus Detectors to
a Zone ID and set basic parameters.
1.
From the main engineer menu press
to enter the
Bus Expander
menu.
2.
Using the arrow and numeric keys select a bus zone expander
ID
.
3.
Using the arrow keys move to
TYPE
. Use the
key to select a
BZE32
and
press
.
Step 2: Adding Bus Detector
Refer to section
Step 1: Adding Bus Detector to the Main Unit
to assign a bus detector
to the system.
Note
When the bus zone is connected to a bus expander, you should define the X in the (x:yy)
display as the bus expander ID (1,2,3 or 4). The yy represents the bus detector ID
number (up to 32) as set by the detector's DIP switches.