Engineer Programming
Page
111
Follow System
The System menu contains Programmable output parameters that follow the System
Event
.
Programmable outputs: System
Quick Keys
Parameter
Bell Follow
Activates when a bell is triggered. If a bell delay was defined, the
programmable output will be activated after the delay period.
No Telephone Line
Activates when a telephone line fault is detected. If a PSTN Lost Delay
time period is defined, the programmable output will be activated after
the delay time.
Communication Failure
Activates when communication with the ARC cannot be established.
Deactivates after a successful call is established with the ARC.
Fault Follow
Activates when a system fault condition is detected.
Deactivates after the fault has been corrected
Main
Low Battery Follow
Activates when the LightSYS rechargeable standby battery has
insufficient reserve capacity and the voltage decreases to 11 V or
following an accessory low battery indication.
AC Loss Follow
Activates when the source of the main panel's AC power is interrupted.
This activation will follow the delay time defined in the system control
times and the AC Off Delay Time parameter (refer to page 63).
Sensors Test
Relates to the LightSYS Zone Self-Test (Quick Keys
)
This option is selected if the designated programmable output is part of
the circuit providing switched power for the source of noise (or
vibration) used in the sensors test procedure.