Keypad Timeout
If, after 15 minutes, no entry is made to a keypad that has been placed in the Engineer
Programming mode, it will produce an audible reminder, consisting of several beeps in
rapid succession, along with the following display:
Time out
Hit any Key
Pressing any key stops the beeping. To re-enter the Engineer Programming menu, you
must key in your Engineer code again and press
.
Accessing Engineer Programming Menu
First Time Power Up
To power up LightSYS for the first time:
1.
Disconnect all power from the main panel
2.
Set SW1 – 2 (Default) to ON position (see page 31).
3.
Set SW1 – 4 (Omit Tamper) to ON position (see page 31).
4.
Connect – power to the assembled mounted unit.
5.
Press the
key.
6.
Select language. Scroll through the options and press
.
Note:
Changing the language can be done also in regular operation mode by pressing
+
simultaneously
7.
Enter the Engineer code (default:
) and press
.
8.
Correct the time and date and confirm by pressing
.
9.
The system automatically enters the automatic accessories settings process option.