IQ MOTION S-LINE INSTALLATION MANUAL

• Advanced circuit technology 

resulting in ultra-low power 
consumption 

• 40 lb. Pet immunity 
• Tamper detection/reporting 

• Rigid wall mounting for discreet 

placement 

• Easy to install batteries 
• Supervisory health messaging

PRODUCT FEATURES

IQ MOTION-S

• Wireless signal range: 600 ft, open air 
• Compatible control panels: Qolsys IQ Panel 2 
• Code outputs: paring, tamper, tamper restore, alarm detect motion, 

alarm restore, supervisory, low battery 

• Transmitter frequency: 319.5MHZ +-15KHz  
• Transmitter bandwidth: 24KHZ 
• Modulation type: ASK-OOK 
• RF output power 91.1dBuV +/- 5% at 3m  
• Sensor Range 30 ft x 40 ft 
• Maximum Horizontal Sensing Angle 80° 
• Sensor: 3.4H x 2.4W x 1.5D in. 
• Replace batteries every 5 years with AAA Alkaline (x2). Detector 

intended for use with (2) Huizhou Deanda Battery Co. AAA LR03.

TECHNICAL SPECIFICATIONS

• The sensor should be permanently mounted in a corner or on a 

flat wall that is free of vibrations, at a height of 6.5 feet, using the 
built-in angle mount. 

• Mount the sensor on an insulated exterior wall facing in. 
• Position the sensor to protect an area where an intruder is most 

likely to walk across the detection pattern. 

• Position the sensor so it faces a solid reference point, such as a 

wall. 

• If possible, mount the sensor within 100 ft of the panel. While 

the transmitter may have a range of 600 ft or more out in the 
open, the environment at the installation site can have a 
significant effect on transmitter range. Verify actual transmitter 
range for each installation. 

• Close all windows in an area with an armed motion sensor. 

STEP 

1

CHOOSE 
INSTALLATION 
LOCATION

• Aim the sensor at windows, fireplaces, 

air conditioners, area heaters, forced 

air heating vents or drapes. 

• Place the sensor in direct sunlight as 

sudden changes in temperature may 

trigger a false alarm. 

• Mount the sensor near duct work or 

other large metallic surfaces that may 

affect the RF signals. 

• Set the sensor on a shelf. 

• Mount outdoors or in a non-

temperature controlled environment. 

• Mount at any other height than 6.5 ft.

Qolsys Inc. proprietary. Reproduction without permission is not permitted.

LOCATION MOUNTING GUIDELINES:

DO NOT: 

X

Avoid placement 
looking at  ceiling 
fans

Outside walls 
pointed away from 
windows are great 
locations

X

Avoid 
HVAC 
ducts & 
drapes

X

Must 

install at 

6.5’  high

Position so that the expected motion is perpendicular to 

the zones of detection. Test yearly.

Note: For UL/CUL installations use this device only in conjunction 

with compatible Qolsys wireless alarm system IQ Panel 2.