IQ MOTION S-LINE INSTALLATION MANUAL
• Advanced circuit technology
resulting in ultra-low power
consumption
• 40 lb. Pet immunity
• Tamper detection/reporting
• Rigid wall mounting for discreet
placement
• Easy to install batteries
• Supervisory health messaging
PRODUCT FEATURES
IQ MOTION-S
• Wireless signal range: 600 ft, open air
• Compatible control panels: Qolsys IQ Panel 2
• Code outputs: paring, tamper, tamper restore, alarm detect motion,
alarm restore, supervisory, low battery
• Transmitter frequency: 319.5MHZ +-15KHz
• Transmitter bandwidth: 24KHZ
• Modulation type: ASK-OOK
• RF output power 91.1dBuV +/- 5% at 3m
• Sensor Range 30 ft x 40 ft
• Maximum Horizontal Sensing Angle 80°
• Sensor: 3.4H x 2.4W x 1.5D in.
• Replace batteries every 5 years with AAA Alkaline (x2). Detector
intended for use with (2) Huizhou Deanda Battery Co. AAA LR03.
TECHNICAL SPECIFICATIONS
• The sensor should be permanently mounted in a corner or on a
flat wall that is free of vibrations, at a height of 6.5 feet, using the
built-in angle mount.
• Mount the sensor on an insulated exterior wall facing in.
• Position the sensor to protect an area where an intruder is most
likely to walk across the detection pattern.
• Position the sensor so it faces a solid reference point, such as a
wall.
• If possible, mount the sensor within 100 ft of the panel. While
the transmitter may have a range of 600 ft or more out in the
open, the environment at the installation site can have a
significant effect on transmitter range. Verify actual transmitter
range for each installation.
• Close all windows in an area with an armed motion sensor.
STEP
1
CHOOSE
INSTALLATION
LOCATION
• Aim the sensor at windows, fireplaces,
air conditioners, area heaters, forced
air heating vents or drapes.
• Place the sensor in direct sunlight as
sudden changes in temperature may
trigger a false alarm.
• Mount the sensor near duct work or
other large metallic surfaces that may
affect the RF signals.
• Set the sensor on a shelf.
• Mount outdoors or in a non-
temperature controlled environment.
• Mount at any other height than 6.5 ft.
Qolsys Inc. proprietary. Reproduction without permission is not permitted.
LOCATION MOUNTING GUIDELINES:
DO NOT:
X
Avoid placement
looking at ceiling
fans
✓
Outside walls
pointed away from
windows are great
locations
X
Avoid
HVAC
ducts &
drapes
X
✓
Must
install at
6.5’ high
✓
Position so that the expected motion is perpendicular to
the zones of detection. Test yearly.
Note: For UL/CUL installations use this device only in conjunction
with compatible Qolsys wireless alarm system IQ Panel 2.