90
Laser Scanners
RF627, RF627Smart [Revision 2.1.2] 20.09.2021
Only one instance of this block is allowed on the graph.
Parameters:
Coils:
“Address”
0...65535
The starting address of the object.
“Count”
0...1968
The number of elements.
“Assembly map”
Output
Distribution of block outputs over the output
assembly. The values of the outputs must be
located in accordance with this parameter.
Discrete
inputs:
“Address”
0...65535
The starting address of the object.
“Count”
0...2000
The number of elements.
“Assembly map”
Input
Distribution of block inputs over the input assembly.
The values of the inputs will be located in
accordance with this parameter.
Input registers: “Address”
0...65535
The starting address of the object.
“Count”
0...125
The number of elements.
“Assembly map”
Input
Distribution of block inputs over the input assembly.
The values of the inputs will be located in
accordance with this parameter.
Holding
registers:
“Address”
0...65535
The starting address of the object.
“Count”
0...123
The number of elements.
“Assembly map”
Output
Distribution of block outputs over the output
assembly. The values of the outputs must be
located in accordance with this parameter.
Inputs:
The inputs are created by the user using the context menu.