20
Laser Scanners
RF627, RF627Smart [Revision 2.1.2] 20.09.2021
17. "Network" tab. Network parameters
To configure the network parameters of the scanner, go to the
Network
tab.
Current Network settings:
Parameter
Factory value
Description
Speed (Mbps)
-
Connection speed. Available modes:
·
10 Mbps;
·
100 Mbps;
·
1000 Mbps.
Autonegotiation
ON
Automatic negotiation of network connection speed.
Current IP settings:
Parameter
Factory value
Description
IP address
192.168.1.30
IP address of the scanner.
Gateway
192.168.1.1
Gateway address.
Subnet mask
255.255.255.0
Network mask.
Host IP address
192.168.1.2
IP address of the PC (or other network device) receiving profiles.
Service port
50011
Scanner port number for the service protocol.
Destination port
50001
Port number of the PC (or other network device) receiving profiles, to
which the scanner must send UDP packets with profiles.
In order for the changes to take effect, it is necessary to click the
Apply
button.