RF627, RF627Smart [Revision 2.1.2] 20.09.2021
Laser Scanners
75
“Angle #2”, deg
“Angle #2 tolerance”, deg
50…150
0...89
Value and permissible deviation of angle #2.
“Angle #3”, deg
“Angle #3 tolerance”, deg
-90…-10
0...45
Value and permissible deviation of angle #3.
“Fillet”:
Group of parameters for the "fillet" template.
Designation of lines and angles:
“Min len (left)”, mm
“Max len (left)”, mm
0,1...1000
0,1...1000
Minimum and maximum length of the segment
to the left.
“Min len (right)”, mm
“Max len (right)”, mm
0,1...1000
0,1...1000
Minimum and maximum length of the segment
to the right.
“Max distance”, mm
0,1...100
Maximum allowable distance between the end
of the left segment and the beginning of the
right one. Minimum allowable distance is 0.
“Angle”, deg
“Angle tolerance”, deg
50…150
0...89
Value and permissible deviation of angle #1.
“Lap left”:
Group of parameters for the "lap left" template.
Designation of lines and angles:
“Min len (segment 1)”, mm
“Max len (segment 1)”, mm
0,1...1000
0,1...1000
Minimum and maximum length of segment #1.
“Min len (segment 2)”, mm
“Max len (segment 2)”, mm
0,1...100
0,1...100
Minimum and maximum length of segment #2.
“Min len (segment 3)”, mm
“Max len (segment 3)”, mm
0,1...1000
0,1...1000
Minimum and maximum length of segment #3.
“Angle #1”, deg
“Angle #1 tolerance”, deg
-150…-30
0...89
Value and permissible deviation of angle #1.
“Angle #2”, deg
“Angle #2 tolerance”, deg
30…150
0...89
Value and permissible deviation of angle #2.
“Lap right”:
Group of parameters for the "lap right"
template. Designation of lines and angles: