Communication Switch 17 (SP No. 1-104-024)
No
Function
Comments
0
SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker's machine using
the SEP (Selective Polling) signal is disabled.
1
SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker's machine
using the SUB (Sub-address) signal is disabled.
2
PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password) signal
reception.
3-4 Not used
Do not change the settings.
5
PSTN dial-in routing setting
0: OFF
1: ON
1: The machine sets multiple PSTN dial-in number in the
PSTN dial-in lien and transfers received data of each
PSTN dial-in number to each address.
6
Not used
Do not change the settings.
7
Action when there is no box with an
F-code that matches the received
SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.
Communication Switch 18 (SP No. 1-104-025)
No
Function
Comments
0-4 Not used
Do not change the settings.
5
IP-Fax dial-in routing selection
0: Off
1: On
1: Transfers receiving data to each IP-Fax dial-in
number.
IP-Fax dial-in number is 4 digit-number.
Bit Switches
97
Summary of Contents for MP C305SPF
Page 1: ...Fax Option Type C305 Machine Code D649 Field Service Manual 28 Dec 2011...
Page 2: ......
Page 8: ...6...
Page 11: ...3 Remove the left cover A x 2 hooks x 2 Fax Unit D649 9...
Page 18: ...3 Press Add Icon 4 Press Select Icon to Add 1 Installation 16...
Page 19: ...5 Press Application 6 Press Facsimile Fax Unit D649 17...
Page 21: ...1 The fax icon is added to the home screen Fax Unit D649 19...
Page 23: ...Installation Procedure 1 Remove the scanner rear cover A x 1 Fax Unit Options 21...
Page 26: ...1 Installation 24...