G3 Switch 0D Not used (do not change the settings).
G3 Switch 0E (SP No. 1-105-015)
No
Function
Comments
0-7
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the 3-second
CNG interval.
High order bit
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) <= N <= FF (2250 ms)
Low order bit
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) <= N <= 0F (3700
ms)
G3 Switch 0F (SP No. 1-105-016)
No
Function
Comments
0
Alarm when an error occurred in
Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each error
communication, change this bit to "1".
1
Alarm when the handset is off-
hook at the end of communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the handset is
off-hook at the end of fax communication, change this
bit to "1".
2-3
Not used
Do not change the settings.
4
Sidaa manual calibration setting
0: Off
1: On
1: manually calibrates for communication with a line,
whose current change occurs such as an optical fiber
line.
5-7
Not used
Do not change the settings.
Bit Switches
107
Summary of Contents for MP C305SPF
Page 1: ...Fax Option Type C305 Machine Code D649 Field Service Manual 28 Dec 2011...
Page 2: ......
Page 8: ...6...
Page 11: ...3 Remove the left cover A x 2 hooks x 2 Fax Unit D649 9...
Page 18: ...3 Press Add Icon 4 Press Select Icon to Add 1 Installation 16...
Page 19: ...5 Press Application 6 Press Facsimile Fax Unit D649 17...
Page 21: ...1 The fax icon is added to the home screen Fax Unit D649 19...
Page 23: ...Installation Procedure 1 Remove the scanner rear cover A x 1 Fax Unit Options 21...
Page 26: ...1 Installation 24...