No
Function
Comments
0-3
Initial Rx modem rate(kbps)
These bits set the initial starting modem rate
for reception.
Use a lower setting if high speeds pose
problems during reception.
If a modem rate 14.4 kbps or slower is
selected, V.8 protocol should be disabled
manually.
Cross reference
V.8 protocol on/off - G3 switch 03, bit2
Bit 3
Bit 2
Bit 1
Bit 0
kbps
0
0
0
1
2.4
0
0
1
0
4.8
0
0
1
1
7.2
0
1
0
0
9.6
0
1
0
1
12.0
0
1
1
0
14.4
0
1
1
1
16.8
1
0
0
0
19.2
1
0
0
1
21.6
1
0
1
0
24.0
1
0
1
1
26.4
1
1
0
0
28.8
1
1
0
1
31.2
Other settings - Not used