Address
Function
Unit
Remarks
6805BD
Modem turn-on level (incoming signal
detection level)
-37-0.5N
(dBm)
6805BE
to
6805C6
Not used
-
Do not change the settings.
6805C7
Bits 0 to 3 – Not used
Bit 4 = V.34 protocol dump 0: Simple, 1: Detailed (default)
Bits 5 to 7 – Not used.
6805C8
to
6805D9
Not used
-
Do not change the settings.
6805DA
T.30 T1 timer
1 s
6805E0 bit
3
Maximum wait time for post message
0: 12 s
1: 30 s
1: Maximum wait time for
post message (EOP/EOM/
MPS) can be changed to
30 s.
Change this bit to “1” if
communication errors occur
frequently during V.17
reception.
6805E3
Voltage setting to detect off-hook for
voltage/DP detection for an externally
connected line.
0: Auto
1: Fixed V
Do not change these
settings
Here is a summary of the fixed voltage settings (1:
Fixed) for an externally connected line.
Bit 7
Bit 6
Bit 5
Bit 4
-
0
0
0
0
Not used
0
0
0
1
2.75 V
0
0
1
0
5.5 V
1
0
0
0
22 V
1
1
1
1
41.25 V
4. Service Tables
128
Summary of Contents for MP C305SPF
Page 1: ...Fax Option Type C305 Machine Code D649 Field Service Manual 28 Dec 2011...
Page 2: ......
Page 8: ...6...
Page 11: ...3 Remove the left cover A x 2 hooks x 2 Fax Unit D649 9...
Page 18: ...3 Press Add Icon 4 Press Select Icon to Add 1 Installation 16...
Page 19: ...5 Press Application 6 Press Facsimile Fax Unit D649 17...
Page 21: ...1 The fax icon is added to the home screen Fax Unit D649 19...
Page 23: ...Installation Procedure 1 Remove the scanner rear cover A x 1 Fax Unit Options 21...
Page 26: ...1 Installation 24...