SERVICE MANUAL
Page 609
CHAPTER 6
9107
May/12
Page 609
Feb/11
CHAPTER 6
283
SERVICE MANUAL
ISO 9650
5.5.2 To apply tape, use exactly the same manner that is used for patches.
Cut a radius on the corners of the tape ends before sticking the
surfaces together; overlap tape ends by 50 mm (2”).
5.6 Repair to insulated f oor retaining straps
Use the following standard repair method, where insulated floor retaining
straps have been fitted to the lower buoyancy ring, to replace them should
they become damaged.
5.6.1 Remove the damaged retaining strap using the method described in
5B, in this Chapter,
5.6.2 Fit the repair strap in the same position and orientation.
NOTE:
Where an insulated floor assembly is not fitted to a
liferaft and the insulated floor retaining straps become
damaged, there is no requirement for repair.
Patch application over seams
FIGURE 603