Page 107
CHAPTER 1
9107
May/12
SERVICE MANUAL
Page 107
Oct/11
CHAPTER 1
ISO 9650
283
SERVICE MANUAL
Container nominal dimensions: (FIGURE 102)
ISO 9650 Type 2
RA
TED
CAP
ACITY
GRP DIMENSIONS THROW OVER RAFTS
<24 hours
mm
Approx.
operation
weight Kg
A
B
C
4
740
420
290
6
740
520
8
740
520
10
820
540
12
N/A
RA
TED
CAP
ACITY
VALISE DIMENSIONS THROW OVER RAFTS
>24 hours
mm
Approx.
operation
weight Kg
A
B
C
4
700
410
260
6
700
500
280
8
700
500
310
10
12
N/A
3. Inf ation system and Gas charges:
(for TPED approved cylinders (Transportable Pressure Equipment Directive))
Liferaft working pressure (Throw Over) ...............................2.8 Psi / 77.5“WG /
.............................................................................................1970 mmWG
INFLATION SYSTEM AND GAS
CHARGES
Kg
Kg
Charging CO
2
Cylinder N
2
4
1.98
0.06
6
2.25
0.09
8
3.38
0.14
10
4.17
0.17
12
4.17
0.17