Page 604
CHAPTER 6
May/12
9107
SERVICE MANUAL
Page 604
Feb/11
CHAPTER 6
283
SERVICE MANUAL
ISO 9650
2. Adhesive
WARNING:
ADHESIVES ARE FLAMMABLE. KEEP AWAY FROM
OPEN
FLAMES AND UNCOVERED LAMPS (NOT PROTECTED BY
LAMP SHADE). USE ONLY IN WELL VENTILATED AREAS.
AVOID CONTACT WITH EYES. AVOID BREATHING FUMES.
USE BARRIER CREAM ON HANDS AND WASH THOROUGHLY
AFTER USE.
2.1 The adhesive to be used for repairing must be of the EV/C2 type.
2.1.1 The adhesive has to be prepared each time in the required quantity.
The adhesive can be used for a maximum of three hours, after
activation through catalyst.
2.1.2 The catalyst should be added to the adhesive in the quantity of 8%
by measure of weight and of 5% by measure of volume.
2.1.3 When the two components have been mixed, shake well until an
even color is achieved. It is important to get a complete blending to
prevent the catalyst from separating.
2.2 EV/C2 adhesive must be used in environments as follows;
(a) Temperature: between 12°C and 35°C;
(b) Relative humidity, not greater than 70%.
WARNING:
AS TEMPERATURE INCREASES, THE CATALYSIS PERIOD
BECOMES SHORTER. AS TEMPERATURE DECREASES THE
CATALYSIS PERIOD BECOMES LONGER.