Page A2-30
APPENDIX 2
May/12
9107
SERVICE MANUAL
Page A2-30
Oct/11
APPENDIX 2
SERVICE MANUAL
283
ISO 9650
3.4 Repair to the H-pack
If the container is failing the vacuum pressure tests, please carry out the
following steps:
3.4.1 Re-apply the vacuum test and check /listen for leaks around the
H-Pack.
3.4.2 Check all welded seams, operating head seals, indicator valve and
vacuum valve.
3.4.3 If a leak is detected, repair it with the heat sealing tool.
3.4.4 Finish the packing process.
3.4.5 Repeat the Post Operational Packing Vacuum Test.
4. Container labelling
4.1 Check that all labels are fitted and positioned correctly and securely
(FIGURE A2-34).
4.2 Record the liferaft details onto the liferaft identification label and insert it into
the identification tube. Check for legibility and correct details.
4.3 The liferaft identification container and any excess tether webbing shall be
placed between the container strapping and the container.
4.4 Tape the IAL compact disc to the container.
4.5 This completes the packing sequence and the liferaft is now ready for
installation.
5. Container IPL
5.1 Please refer to TABLE A2-01 for Flat pack container part numbers and
assessories.