Page 410
CHAPTER 4
May/12
9107
SERVICE MANUAL
Page 410
Oct/11
CHAPTER 4
283
SERVICE MANUAL
ISO 9650
2.3 Emergency pack (lifed items)
NOTE:
Each of the items given below may not be supplied in
some emergency packs. Refer to the contents label for
the contents of the pack.
2.3.1 Revere Supply state that any ‘lifed’ item that has less than 24
months life remaining, it MUST be replaced in the emergency pack.
2.3.2 Discard any stock which is out-of-date, as given in the applicable
regulations of the country.
2.3.3 Check correct pyrotechnics are being used. Only the pyrotechnics
that are listed as an approved supplier are permitted.
Check the pyrotechnics for general condition. Any pyrotechnics with
dents, corrosion or other visible damage should be replaced.
2.3.4 Check the handbooks and leaflets. Make sure they are in good
condition and legible.
2.3.5 Test the Whistle and Bellows. Make sure they function correctly and
are not damaged. Ensure any adaptor required is fitted to the bellows
and is suitable for the top up valve fitted.
2.3.6 Test the torch/flashlight and batteries. Make sure they function
correctly and are not damaged.
NOTE:
Check the expiry date on the torch batteries. If the
expiry date will be reached before the next scheduled
service, replace the batteries.
2.3.7 Check the first aid kit, bailers and paddles. Make sure they are not
corroded or damaged. If necessary, replace any defective parts.
2.3.8 Examine the repair kit, for damage to the contents. If necessary,
replace any damaged items.
2.3.9 Visually check water sachets for any signs of damage, squeeze
sachets and check for leaks.