SERVICE MANUAL
Page 409
CHAPTER 4
9107
May/12
Page 409
Feb/11
CHAPTER 4
283
SERVICE MANUAL
ISO 9650
2.2.5 If the Internal lamp unit is damaged, or is emitting an odor, remove it
as follows:
WARNING:
PUT ON PROTECTIVE CLOTHING AND EQUIPMENT TO
COVER EYES, HANDS AND BODY. THE CONTENTS OF
THE BATTERY CAN CAUSE INJURY. REFER TO THE
MANUFACTURER’S DATA SHEET.
NOTE:
Make sure there is good air flow in the work area.
(a) Put the defective unit in a cool area. Let it stand for
approximately 24 hours. After this time the power unit should be
odorless.
(b) Insulate the electrical connections. Put the unit in a strong
plastic bag or container to seal it from the atmosphere.
(c) Discard the unit as given in the applicable regulations of the
country.
2.2.6 Check the External lamp unit. Make sure the leads and connections
have no signs of damage or deterioration.
2.2.7 Illuminate the External lamp using the switch marked ‘external’ on the
side of the Internal lamp unit. (FIGURE 402). If the LED lamp in the
External lamp unit fails to illuminate, replace the unit.