SERVICE MANUAL
Page 207
CHAPTER 2
9107
May/12
Page 207
Oct/11
CHAPTER 2
283
SERVICE MANUAL
ISO 9650
3.2.9 Unscrew the clamp nut on the operating head. This will allow the
cylinder to be removed, (FIGURE 206).
3.2.10 Unroll the liferaft out of the container onto the packing table. Untie
and remove the Emergency packs, (FIGURE 207).
3.2.11 CAREFULLY lift the liferaft out of the H-pack. Lift the raft out of the
container and onto a packing table.
3.2.12 Disconnect the inflation hoses. Fit the cylinder protection cap and the
recoil caps then remove the cylinder from the liferaft, (FIGURE 208).
WARNING:
HOLD THE GAS CYLINDER IN A VICE OR SAFE CLAMPING
MECHANISM WHEN INSTALLING OR REMOVING AN
OPERATING HEAD.
3.2.13 CAREFULLY remove the operating head, (FIGURE 208).
3.2.14 Retain the nut, O-ring and plastic washer for re-packing.
3.2.15 The rubber washer, should be discarded. A new washer is required
for re-packing.
3.2.16 Remove and discard the H-pack and the foam linings from the
container.
3.2.17 Unfold the liferaft, disconnect all the power unit activation cords
from the attachment patch on the floor. Keep the pins in their
switch blocks. Remove the adhesive tape securing the lighting plug
connectors and withdraw them.
3.2.18 Remove all dessicant packs from the liferaft and container and
discard.